Storage Details
  frontend ports backend bus/ports backend disks
Silicon Gear FC: 2 X 1Gbs SCSI: split bus 2 X 5+1 R5
Dot Hill FC: 2 X 1Gbs FC: 2 X 1Gbs 2 X 6-way R0
YottaYotta FC: 8 X 2Gbs FC: 8 X 2Gbs 28-way R0
Raw Performance (w/ 8 clients)
  Dot Hill Silicon Gear Yotta Yotta
Cache Write 59.81 135.63 795.35
Cache Read 143.07 66.06 1480.07
Cache Rotate Read 144.48 83.29 233.55
Disk Write 53.75 28.87 733.35
Disk Read 131.37 85.33 267.95
Disk Rotate Read 127.23 86.58 240.97